Özelliklere genel bakış
-
Spectral coverage
Starter:
300-3300 cm-1 (785 nm)
Base Model:
150-4350 cm-1 (532 nm)
150-3425 cm-1 (785 nm)
200-2400 cm-1 (1000 nm)
Hybrid: 175-1890 cm-1 (785 nm)
Uygulama alanı
Adeptly harness the power of Raman spectroscopy with the Raman Rxn2 analyzer. Designed for use in analytical laboratories with model transfer capabilities, the Raman Rxn2 is heavily relied on for routine sample identification, support of R&D projects, early process development, and scale-up settings for in situ analysis. Available as a benchtop or on a mobile wheeled cart, the Raman Rxn2 offers location convenience and portability for process development laboratories.
Chemical: polymerization, extrusion monitoring, polymer blending, catalysis investigation
Pharmaceutical: reaction chemistry, yield crystallization, polymorph, blending, drying, granulations
Biopharmaceutical: bioprocess monitoring and control, PAT/QbD applications, cell culture, fermentation, downstream operations, cGLP/cGMP compatible
Food & Beverage: cultured meat, fermentation, oil or fat quality
Avantajlar
Reliable real-time, in situ measurements
Intuitive, embedded control software via touchscreen or remote interface
Convenience of a single base unit supporting up to four probes
-
Sequential operation for fast analysis per channel and programmable channel interrogation
Converts acquired Raman spectra into process knowledge using built-in multivariate predictors
Suitable for outputs into hazardous area/classified environments
Proven model transferability to process development and manufacturing scales
Extended seçim
-
Üst düzey ürünler
- Son derece fonksiyonel ve uygun
Teknik mükemmellik
Sadelik
-
Özelleştirilmiş ürünler
- Zorlu uygulamalar için tasarlanmış
Teknik mükemmellik
Sadelik
Değişken
FLEX seçimleri | Teknik mükemmellik | Sadelik |
---|---|---|
Fundamental seçim Temel ölçüm ihtiyaçlarınızı karşılayın |
Teknik mükemmellik
|
Sadelik
|
Lean seçim Ana proseslerinizin üstesinden kolayca gelin |
Teknik mükemmellik
|
Sadelik
|
Extended seçim Proseslerinizi yenilikçi teknolojilerle optimize edin |
Teknik mükemmellik
|
Sadelik
|
Xpert seçim En zorlu uygulamalarınızda uzmanlaşın |
Teknik mükemmellik
|
Sadelik
Değişken |
-
-
Teknik Bilgiler (TI)
Raman Rxn2 Technical Information
System design and specifications for the Raman Rxn2 analyzer -
powered by Kaiser Raman technologyDil:
İngilizce
Versiyon:
21/11/2023
Dosya boyutu:
1.2 MB
Dosya adı:
TI01608CEN_0323.pdf
-
-
-
Kullanma Talimatı (BA)
Raman RunTime v6.5 Operating Instructions
Commissioning, operation, and maintenance details
for Raman RunTime v6.5 softwareEN TR 16/11/202316/11/202231/12/2020Dil:
İngilizce
Versiyon:
16/11/2023
Dosya boyutu:
6.7 MB
Dosya adı:
BA02180CEN_0423.pdf
-
-
-
Kullanma Talimatı (BA)
Raman Rxn2 Operating Instructions
Commissioning, operation, and maintenance details for the
Raman Rxn2 analyzer - powered by Kaiser Raman technologyDil:
İngilizce
Versiyon:
21/03/2024
Dosya boyutu:
9.1 MB
Dosya adı:
BA02151CEN_0524.pdf
-
-
-
Kısa Talimat (KA)
Raman Rxn2 Brief Operating Instructions
Quick start guide for the Raman Rxn2 analyzer -
powered by Kaiser Raman technologyDil:
İngilizce
Versiyon:
21/11/2023
Dosya boyutu:
2.5 MB
Dosya adı:
KA01544CEN_0323.pdf
-
-
-
Ex Güvenlik Talimatı (XA)
Raman Rxn2 Safety Instructions
Hazardous area certifications and installation instructions
for the Raman Rxn2 analyzer - powered by Kaiser Raman technologyDil:
İngilizce
Versiyon:
07/12/2023
Dosya boyutu:
1.1 MB
Dosya adı:
XA02700CEN_0323.pdf
-
-
-
PU (Yayın)
Kaiser Raman technology and Sartorius BioPAT Spectro® collaboration Q&A - Scalable, real-time bioprocess monitoring solutions
A Q&A about how our Raman spectroscopy analyzer systems
(including the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
and Rxn-46 probe), powered by Kaiser Raman technology, integrates
with the Sartorius BioPAT Spectro platform (Ambr and biostat STR) for
high throughput and single use (SUB) bioprocessingin the
biopharmaceutical life science industry.Dil:
İngilizce
Versiyon:
08/12/2021
Dosya boyutu:
943.7 KB
Dosya adı:
PU01446CEN_0121.pdf
-
-
-
PU (Yayın)
Advanced process and product control in fermentations - Raman spectroscopy for composition analysis in a lab or process
An overview of Raman spectroscopy analyzer systems (including the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe, and Rxn-45
probe), powered by Kaiser Raman technology, for fermentation
compositional analysis in a lab or process applicable to biotechnology
in the food & beverage industry.Dil:
İngilizce
Versiyon:
03/03/2022
Dosya boyutu:
603 KB
Dosya adı:
PU01457CEN_0122.pdf
-
-
-
PU (Yayın)
Raman application guide for the life science industry - Trusted composition analysis for the life sciences
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).Dil:
İngilizce
Versiyon:
19/04/2022
Dosya boyutu:
1.1 MB
Dosya adı:
PU01447CEN_0222.pdf
-
-
-
PU (Yayın)
Lab-to-process monitoring & control in Life Sciences - Reliable measurement of bioprocess physical and chemical properties
A combined product list of analysis offerings from both Optical Analysis
and Liquid Analysis for bioprocessing applications in the life science
industry (including Raman Rxn2 analyzer, Raman Rxn4 analyzer,
Rxn-10 probe, bIO-Optic, Rxn-45 probe, Rxn-46 probe, Raman optic
system for single use, Memosens CPS61E, Memosens COS81E, OUSBT66,
Memosens CPS61E, Memosens CPS77E, Memosens CLS82E, OUSAF44,
Memosens CPS11E, Memosens CLS16E, TOC Analyzer CA79, Liquiline
transmitter platform, and Memobase software).Dil:
İngilizce
Versiyon:
10/08/2022
Dosya boyutu:
782.3 KB
Dosya adı:
PU01484CEN_0122.pdf
-
-
-
PU (Yayın)
Raman flow assembly - Precise composition measurement of high-speed, low-volume samples in downstream bioprocessing
An overview of the Raman flow assembly (flow bench and flow cell)
used with the Rxn-10 probe in conjunction with a Raman Rxn2
analyzer and a Raman flow assembly calibration and verification kit
for downstream bioprocessing (powered by Kaiser Raman technology).Dil:
İngilizce
Versiyon:
31/05/2023
Dosya boyutu:
837 KB
Dosya adı:
PU01517CEN_0123.pdf
-