The Raman Rxn-40 probe is a sealed immersion probe for in situ Raman spectroscopy of liquid-phase samples in a laboratory or process plant setting. The process connection for the Raman Rxn-40 can be swaged, compression-mounted, flange-mounted, or installed in an Endress+Hauser flow cell, and is NeSSI compatible. These versatile options allow for direct insertion in slip-streams, drain-values, reactors, circulation loops, blend headers, and inlet or outlet pipework.
Chemical: reaction monitoring, blending, catalysis, feed and final product monitoring
Pharmaceutical: API reaction monitoring, crystallization, polymorph, blending
Avantajlar
Customizable to your process
Robust design with a range of process connections
In situ/no transfer lines or fast-loops required
Faster, simpler installation
Support for a range of chemical processes and corrosivity requirements
Ensures safety and meets regulatory requirements
Suitable for hazardous/classified environments
Raman spektroskopisi - gelişmiş optik analiz teknolojisi
Tesis güvenliğini artırın, ürün kalitesini sağlayın ve operasyonları optimize edin. Raman spektroskopisi, numunelerinizin bileşimini ve moleküler yapısını laboratuvardan prosese gerçek zamanlı olarak ölçer.
Learn how Raman Spectroscopy can provide analysis solutions for challenging stream conditions, by reading the white paper focused on two different customer case studies.
Kimya endüstrisinde faaliyet gösteren Melamin, tankerlerden doğru tanklara sevkiyatının doğru bir şekilde sağlanması için solvent transferlerini izler.
Probe spectral coverage is limited by the coverage of the analyzer being used.
Ambient temperature
Nonexplosive environments: -30 to 70 °C / -22 to 158 °F Explosive environments: T3/T4: –20 to 70 °C / –4 to 158 °F T6: –20 to 65 °C / –4 to 149 °F Limited to normal ambient temperature IEC 60079-0 for Korea
Maximum laser power into probehead (mW)
< 499
Sample interface
Temperature, Rxn-40 mini configuration: -30 to 120 °C / -22 to 248 °F (316L stainless steel) -30 to 150 °C / -22 to 302 °F (C276 alloy) -30 to 150 °C / -22 to 302 °F (Grade 2 Titanium) Temperature ramp: ≤ 30 °C/min ≤ 54 °F/min Temperature, Rxn-40: -30 to 120 °C / -22 to 248 °F (316L stainless steel) -30 to 280 °C / -22 to 536 °F (C276 alloy) -30 to 315 °C / -22 to 599 °F (Grade 2 Titanium) Temperature ramp: ≤ 30 °C/min ≤ 54 °F/min Flange: ASME B16.5 and DIN EN1092 Type B flanges available upon request Relative humidity: up to 95%, non-condensing
Pressure
Min pressure: Full vacuum (0 bara) but not ultrahigh vacuum (UHV) where outgassing may be a concern Max pressure, Rxn-40 mini configuration: 157.1 barg/ 2279 psig (316L stainless steel) 199.3 barg/ 2890 psig (C276 alloy) 153.6 barg/ 2228 psig (Grade 2 titanium) Max pressure, 1/2 inch Rxn-40: 142.4 barg/ 2066 psig (316L stainless steel) 158.1 barg/ 2293 psig (C276 alloy) 65.2 barg/ 946 psig (Grade 2 titanium) Max pressure, 3/4 and 1 inch Rxn-40: 169.5 barg/ 2458 psig (316L stainless steel) 182.8 barg/ 2651 psig (C276 alloy) 72.2 barg/ 1047 psig (Grade 2 titanium)
Raman-Anwendungsleitfaden für die
Life-Sciences-Industrie
PU (Yayın)
Türkçe versiyonu - 09/2025
New version available in English
Ein Leitfaden zu unseren Anwendungshinweisen zur Raman-Spektroskopie für die Life-Science-Industrie (Raman Rxn2-Analysator, Raman Rxn4-Analysator, Rxn-10-Sonde, Rxn-20-Sonde, Rxn-45-Sonde, Rxn-46-Sonde und Zubehör für Sondenoptiken (blO-Optic, Raman- Single Use-Optiksystem / SUB, Immersionsoptik, berührungslose Optik)
An overview brochure about our Raman Rxn5 analyzer (including the Raman Rxn-30 probe, the Rxn-40 probe,), a Raman spectroscopy analyzer system for gas phase measurements powered by Kaiser Raman technology.
Raman spectroscopy installation in hazardous areas (ATEX,
IECEx, NEC/CEC)
PU (Yayın)
İngilizce versiyonu - 04/2026
New version available in English
This learning article explains how Raman spectroscopy systems are safely installed in hazardous areas to meet ATEX, IECEx, and North American standards.