  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    metric style
    modular temperature assembly
    hygienic design
    suitable for hazardous areas
    hygienic process connection
    with neck
    incl. thermowell / protection tube (metal)

  • Thermowell / protection tube

    welded protection tube

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    9,0 mm (0,35'')

  • Max. immersion length on request

    up to 4.000,00 mm (157,48'')

  • Material protection tube/ thermowell

    1.4435 (316L)

  • Optional coating

    Tantal

  • Process connection

    hygienic:
    conical sealing system G1/2" (metal)
    clamp connections acc. to ISO 2852 / DIN 32676
    clamp connections TRI-Clamp / Micro-Clamp
    screwed pipe joint acc. to DIN 11851
    screwed pipe joint acc. to DIN 11864-1
    Varivent
    SMS 1147/8
    G1" Liquiphant type M
    Ingold
    welded (cylindircal)
    welded (spherical)

  • Tip shape

    straight
    reduced
    tapered

  • Surface roughness Ra

    0,4 μm (15,7 μin.)
    0,8 μm (31,5 μin.)

  • Operating temperature range

    PT 100:
    -50 °C ...400 °C
    (-58 °F ... 752 °F)

  • Max. process pressure (static)

    at 20 °C: 50 bar (725 psi)

  • Accuracy

    class A acc. to IEC 60751
    1/3 DIN class B acc. to IEC 60751

  • Response time

    depending on configuration

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX II
    NEPSI
    IECEx

  • Certification

    Gost Metrology
    FDA
    EHEDG
    3A
    SIL (transmitter only)

Dokümanlar / Kılavuzlar / Yazılım

Aksesuarlar / Yedek parçalar

Nr
Order code
Specification
  • C
  • A
    • Nr A Order code TPR100-

      Insert TPR100

      Mineral insulated cable (MgO). Replaceable insert acc.EN60751. max. measuring range: -200...600oC (depending on configuration).

  • E
    • Nr E Order code TT411-

      iTHERM TT411 Thermowell

      Thermowell with hygienic design. Metrical version for applications in the food/beverages and pharmaceutical industries.

  • D
    • Nr D Order code TA20A-

      Terminal Head TA20A

      Product being phased out, limited availability. Connection head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material: Aluminium epoxy resin coating Area temperature : max. +100 oC; ATEX: +95 oC.

    • Nr D Order code TA20B-

      Terminal Head TA20B

      Connecting head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material:Polyamid black. Ambient temperature: max. +80 oC. Protection: IP65.

    • Nr D Order code TA21E-

      Terminal Head TA21E

      Retainer for terminal block or head transmitter. Cover: srewable. Material: aluminum. Max. temp.: +100 oC; ATEX +95 oC. Protection: IP65.

  • B
    • Nr B Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.

    • Nr B Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr B Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr B Order code TID10-

      Display Unit Head Transmitter

      to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82, TMT71, TMT72.

  • D
    • Nr D Order code TA30A-

      Terminal Head TA30A

      Retainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).

    • Nr D Order code TA30D-

      Terminal Head TA30D

      Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).

  • B
    • Nr B Order code TMT180-

      iTEMP TMT180, Head Transmitter Pt100

      Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr B Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Product being phased out, limited availability. Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr B Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Product being phased out, limited availability. Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

  • Önceki seri

  • Yeni seri

    • Basit ürünler

    • Seçmesi, kurması ve çalıştırması kolay

    Teknik mükemmellik

    Sadelik

    • Standart ürünler

    • Güvenilir, sağlam ve az bakım gerektiren

    Teknik mükemmellik

    Sadelik

    • Üst düzey ürünler

    • Son derece fonksiyonel ve uygun

    Teknik mükemmellik

    Sadelik

    • Özelleştirilmiş ürünler

    • Zorlu uygulamalar için tasarlanmış

    Teknik mükemmellik

    Sadelik

    Değişken

    FLEX seçimleri Teknik mükemmellik Sadelik
    • F
    • L
    • E
    • X

    Fundamental seçim

    Temel ölçüm ihtiyaçlarınızı karşılayın

    Teknik mükemmellik
    Sadelik
    • F
    • L
    • E
    • X

    Lean seçim

    Ana proseslerinizin üstesinden kolayca gelin

    Teknik mükemmellik
    Sadelik
    • F
    • L
    • E
    • X

    Extended seçim

    Proseslerinizi yenilikçi teknolojilerle optimize edin

    Teknik mükemmellik
    Sadelik
    • F
    • L
    • E
    • X

    Xpert seçim

    En zorlu uygulamalarınızda uzmanlaşın

    Teknik mükemmellik
    Sadelik

    Değişken