Özelliklere genel bakış
-
Process temperature
0 to 60 °C (32 to 140 °F)
Uygulama alanı
The Flexdip CYA112 is a modular assembly for sensor immersion in open basins, channels, or tanks. It allows nearly any kind of sensor mounting – chain, fixed, or free-swinging – and features a quick fastener for rapid and safe installation of Memosens or fixed-cable sensors. The assembly provides you with outstanding flexibility and enables you to optimally configure your measurement at low costs.
Flexdip CYA112 is a modular assembly for all measurements in open basins, channels and tanks in:
Wastewater treatment plants
Water works
Utilities of all industries
It forms a perfect team with the Flexdip CYH112 holder for simple sensor isolation.
The Flexdip team is suitable for all parameters, such as:
pH/ORP
Conductivity
Oxygen
Turbidity
Sludge level
Disinfection
UV photometry
Nutrients
Avantajlar
The modular system allows an optimum configuration for every measuring place
Fast installation and exchange of Memosens sensors with contactless plug-in head
Twist-free installation of fixed-cable sensors
Easy to install and to maintain
-
Özelleştirilmiş ürünler
- Zorlu uygulamalar için tasarlanmış
Teknik mükemmellik
Sadelik
Değişken
| FLEX seçimleri | Teknik mükemmellik | Sadelik |
|---|---|---|
Fundamental seçim Temel ölçüm ihtiyaçlarınızı karşılayın |
Teknik mükemmellik
|
Sadelik
|
Lean seçim Ana proseslerinizin üstesinden kolayca gelin |
Teknik mükemmellik
|
Sadelik
|
Extended seçim Proseslerinizi yenilikçi teknolojilerle optimize edin |
Teknik mükemmellik
|
Sadelik
|
Xpert seçim En zorlu uygulamalarınızda uzmanlaşın |
Teknik mükemmellik
|
Sadelik
Değişken |
Önceki seri
-
Measuring principle
Potentiometric
-
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
-
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
-
Characteristic
Simple and easy installation
Universal and flexible -
Design
Versions in stainless steel or PVC
-
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM -
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch) -
Process temperature
0 to 60 °C (32 to 140 °F)
-
Measuring principle
Sensor ORP / Redox
-
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
-
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
-
Characteristic
Simple and easy installation
Universal and flexible -
Design
Versions in stainless steel or PVC
-
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM -
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch) -
Process temperature
0 to 60 °C (32 to 140 °F)
-
Measuring principle
Conductive
-
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
-
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
-
Characteristic
Simple and easy installation
Universal and flexible -
Design
Versions in stainless steel or PVC
-
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM -
Dimension
Tauchrohr Durchmesser: 40 mm (1.57 Zoll)
Länge: 600, 1200, 1800 und 2400 mm
(23.6, 47.2, 70.9 und 94.5 Zoll) -
Process temperature
0 ... 60 °C (32 ... 140 °F)
-
Measuring principle
Amperometric oxygen measurement
-
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
-
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
-
Characteristic
Simple and easy installation
Universal and flexible -
Design
Versions in stainless steel or PVC
-
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM -
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch) -
Process temperature
0 to 60 °C (32 to 140 °F)
-
Measuring principle
Total chlorine
-
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
-
Characteristic
Simple and easy installation
Universal and flexible -
Design
Versions in stainless steel or PVC
-
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM -
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch) -
Process temperature
0 to 60 °C (32 to 140 °F)
-
Measuring principle
Single beam scattered light
-
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
-
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
-
Characteristic
Simple and easy installation
Universal and flexible -
Design
Versions in stainless steel or PVC
-
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM -
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch) -
Process temperature
0 to 60 °C (32 to 140 °F)
-
Measuring principle
UV photometric
-
Characteristic
Simple and easy installation
Universal and flexible -
Design
Versions in stainless steel or PVC
-
Process temperature
0 to 60 °C (32 to 140 °F)
-
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
-
-
Teknik Bilgiler (TI)
Flexdip CYA112
-
Teknik Bilgiler (TI)
İngilizce versiyonu - 12/2019New version available in EnglishImmersion assembly for water and wastewater
EN TR 13/12/201929/05/201201/05/2009Dil:
İngilizce
Versiyon:
13/12/2019
Dosya boyutu:
708.9 KB
Dosya adı:
TI00432CEN_1419.pdf
-
-
-
Kullanma Talimatı (BA)
Flexdip CYA112
-
Kullanma Talimatı (BA)
Türkçe versiyonu - 12/2019New version available in EnglishAtık su düzeneği
EN TR 13/12/201921/08/201301/05/2009Dil:
Türkçe
Versiyon:
13/12/2019
Dosya boyutu:
958.3 KB
Dosya adı:
BA00432CTR_1419.pdf
-
-
-
Kurulum talimatları (EA)
Kit manual for sample preparation systems CAT8xx Filter
-
Kurulum talimatları (EA)
İngilizce versiyonu - 01/2026New version available in EnglishKit manual for sample preparation systems CAT8xx Filter - two-sided
EN TR 16/01/2026Dil:
İngilizce
Versiyon:
16/01/2026
Dosya boyutu:
2.1 MB
Dosya adı:
71223012 Anleitung Kits CAT8xx Filter 2020-06.pdf
-
-
-
Faaliyet Alanları (FA)
Sensors, transmitters, compact devices and assemblies
-
Faaliyet Alanları (FA)
İngilizce versiyonu - 02/2026New version available in EnglishExperts in Liquid Analysis
Dil:
İngilizce
Versiyon:
02/02/2026
Dosya boyutu:
4.2 MB
Dosya adı:
FA00007C_EN_Analyse_22-26_LowRes.pdf
-
-
-
Faaliyet Alanları (FA)
Sensoren, Messumformer, Kompaktgeräte and Armaturen
-
Faaliyet Alanları (FA)
Türkçe versiyonu - 02/2026New version available in EnglishKompetenz in der Flüssigkeitsanalyse
Dil:
Almanca
Versiyon:
02/02/2026
Dosya boyutu:
4.3 MB
Dosya adı:
FA00007C_DE_Analyse_22-26_LowRes.pdf
-
-
-
Faaliyet Alanları (FA)
Endress+Hauser 水質分析計ファミリ
-
Faaliyet Alanları (FA)
Japonca versiyonu - 03/2017New version available in Englishラインナップと事例
Dil:
Japonca
Versiyon:
23/03/2017
Dosya boyutu:
34.8 MB
Dosya adı:
FA00007CJA_2022_Endress Hauser liquid analysis family.pdf
-
-
-
Yetkinlik Broşürü (CP)
pH-Messung in Industrieprozessen
-
Yetkinlik Broşürü (CP)
Türkçe versiyonu - 12/2021New version available in EnglishAuswahl- und Engineering-Hilfe für verschiedene Industriebranchen und
ApplikationenDil:
Almanca
Versiyon:
01/12/2021
Dosya boyutu:
3.3 MB
Dosya adı:
CP00010CDE_1621_pH Auswahlhilfe_2021.pdf
-
-
-
Yetkinlik Broşürü (CP)
産業プロセスにおける導電率の測定
-
Yetkinlik Broşürü (CP)
Japonca versiyonu - 01/2024New version available in Englishさまざまな産業およびアプリケーション向けの選択およびエンジニアリングガイド
Dil:
Japonca
Versiyon:
12/01/2024
Dosya boyutu:
3.5 MB
Dosya adı:
CP01313CJA_0223_1024_Conductivity_sensor_selection_guide.pdf
-
-
-
Yetkinlik Broşürü (CP)
pH measurement in industrial processes
-
Yetkinlik Broşürü (CP)
İngilizce versiyonu - 12/2021New version available in EnglishSelection and engineering guide for different industries and
applicationsDil:
İngilizce
Versiyon:
02/12/2021
Dosya boyutu:
3.2 MB
Dosya adı:
CP00010CEN_1621_pH selection guide_2021.pdf
-
-
-
Yetkinlik Broşürü (CP)
産業プロセスにおけるpH測定
-
Yetkinlik Broşürü (CP)
Japonca versiyonu - 02/2024New version available in Englishさまざまな産業およびアプリケーション向けのpH測定セレクションガイド
Dil:
Japonca
Versiyon:
08/02/2024
Dosya boyutu:
2.6 MB
Dosya adı:
CP00010CJA_1315_1024_pH_selection_guide.pdf
-
Önerdiğimiz seçeneklerden birini seçin
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD çizimleri CAD çizimleri
- CAD çizimleri
-
Parça başına fiyat
-
<%range%><%price%>
-
- Opsiyonel eklentiler
Ayrı konfigürasyon
Genellikle birlikte satın alınanlar
Aksesuarlar
Benzer ürünler