Using patented tunable diode laser spectroscopy (TDLAS) technology, the SS500 analyzer is an economical choice for measuring H2O concentration in natural gas without coming into physical contact with the stream. The result is a sensor that does not suffer from contamination or drift due to vapor impurities such as glycol, methanol, or amines.
Natural gas quality measurements in production, storage, transportation, and distribution
Monitoring for natural gas pipelines, processing plants, compressor stations, gathering sites, and distribution quality
Suitable for use as a check-measurement device
Measurable ranges of up to 0.25 – 100 lb/mmscf (5 – 2110 ppmv)
Avantajlar
Economical real-time moisture measurements
Virtually maintenance-free
Reliable in harsh environments
Fast and accurate with no wet-up or dry-down delays
No contamination or drift due to vapor impurities such as glycol, methanol, amines, hydrogen sulfide, or mercaptans
NIST-traceable calibration with analog and serial outputs for remote monitoring
CSA certified for CSA Class 1, Division 2 or Class 1, Division 1
Tesis güvenliğini ve kullanılabilirliğini optimize edin. Ayarlanabilir diyot lazer absorpsiyon spektroskopisi (TDLAS), proses gaz akışlarındaki konsantrasyonları gerçek zamanlı olarak hızlı ve güvenilir bir şekilde ölçer.
An economical gas analyzer for moisture (H2O) in the natural gas industry. The sensor measures gas using tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream. Option of simplified sample conditioning to reduce complexity of the analyzer system.
Channels
1
Analyte and measurement ranges
H2O (Moisture): 5 to 422 ppmv (minimum) 5 to 2110 ppmv (maximum)
Measured variables
Concentration Dew Point Cell Pressure Cell Temperature
Ambient temperature range
-20 to 50°C (-4 to 122°F)
Operating pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig) Sample Cell: 700 to 1400 mbara
Analyzer wetted materials
316L stainless steel FKM O-Rings Glass
Power supply
100 to 240 VAC, 50 to 60 Hz or 9 to 16 VDC or 18 to 32 VDC - optional 1 Amp maximum at 120 VAC 1.6 Amps at 24VDC, 3.2 Amps at 12 VDC
Communication
Analog Output: 1 or 2 4-20mA Isolated, 1200 ohms at 24 VDC max load Serial: RS232C Protocol: Modbus Gould RTU or Daniel RTU or ASCII Alarms: 2, General Fault and Concentration Alarms via Modbus and Analog Output(s)
Housing materials
Electronics: 304 stainless steel (Class I Division 2) Sample System Panel: anodized aluminum
An overview about the engineered approval drawings offered for TDLAS and QF analyzers (SS2100, SS2100i, J22, JT33, OXY5500, SS500) to enable customers to confirm that the system fabrication meets their approval.
Seçiminize mümkün olan tüm seçeneklerle devam edin
Gizliliğinize değer veriyoruz
Tarayıcı deneyiminizi iyileştirmek, site işlevselliğini optimize etmek adına istatistikleri toplamak ve size uygun reklam ve içerikler göstermek için çerezleri kullanıyoruz.
"Tümünü kabul et" seçeneği ile çerez kullanımımıza rıza göstermiş olursunuz.
Daha fazla ayrıntı için lütfen göz atın: Çerez Politikamız .