Levelflex M FMP43
This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Dokümanlar / Kılavuzlar / Yazılım
-
Weld-in adapter, process adapter and flanges
Level and pressure measurement
Technical Information (TI) -
Levelflex M FMP43
Technical Information
Guided Level-Radar
Continuous Level Transmitter for continuous level measurement
in liquids in hygienic applications.Technical Information (TI) -
Levelflex M FMP43
HART
Operating Instructions
Guided Level Radar
Continuous Level Transmitter for continuous level measurement in liquids
in hygienic applications.Operating Instruction (BA) -
Accessory
Weld-in adapter
Operating Instruction (BA) -
Levelflex M FMP43
FOUNDATION Fieldbus
Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for continuous level measurement in liquids
in hygienic applications.Operating Instruction (BA) -
Levelflex M FMP43
Calibration kit
Operating Instruction (BA) -
Levelflex M FMP43
Accessory
Operating Instruction (BA) -
Levelflex M FMP40, FMP41C, FMP43, FMP45
HART, PA, FF
Description of Instrument Functions
Smart Transmitter for continuous
level measurement in liquidsOperating Instruction (BA) -
Levelflex M FMP43
PROFIBUS PA
Operating Instructions
Guided Level Radar
Continuous Level Transmitter for continuous level measurement in liquids
in hygienic applications.Operating Instruction (BA) -
Levelflex M FMP43
FOUNDATION Fieldbus
Brief
Operating Instructions
Guided Level Radar
Continuous Level Transmitter for continuous level measurement in liquids
in hygienic applications.Short Instruction (KA)11/10İngilizce -
Levelflex M FMP43
PROFIBUS PA
Brief Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for continuous level measurement in liquids
in hygienic applications.Short Instruction (KA)11/10İngilizce -
Levelflex M FMP43
HART
Brief Operating Instructions
Guided Level Radar
Continuous Level Transmitter for continuous level measurement in liquids
in hygienic applications.Short Instruction (KA)11/10İngilizce -
Weather protection cover
Mounting Instruction
Weather protection cover for devices with F12/T12/F23 housing.
Short Instruction (KA)06/07Almanca , İngilizce , İspanyolca , fr , İtalyanca , Flemenkçe -
Exchange of rod probe and process connection on FMP43
Exchange of rod probe and process connection on FMP43
Short Instruction (KA)04/12Almanca , İngilizce -
Levelflex M FMP40, FMP41C, FMP43, FMP45
HART, PROFIBUS PA, FOUNDATION Fieldbus
Leveflex M Kurzanleitung/Brief operating instructions
HART, PROFIBUS PA, FOUNDATION FieldbusShort Instruction (KA)03/07Almanca , İngilizce -
Bushing PEEK
Installation instruction
Levelflex M FMP43
Installation Instructions (EA) -
HF module
Installation instruction
Levelflex M
Installation Instructions (EA) -
Sensor body for FMP43
Installation instruction
Levelflex M
Installation Instructions (EA) -
Electronics for Levelflex M
Installation instruction
Levelflex M
Installation Instructions (EA) -
Terminal module for housing F12/F23
Installation Instruction
Micropilot M, Levelflex M, Prosonic M
Installation Instructions (EA) -
Cable separate version
Installation Instructions
Cerabar M, Cerabar S, Deltabar S, Deltapilot M, Deltapilot S
Installation Instructions (EA) -
Cover F23
Installation instruction
Levelflex M, Micropilot M
Installation Instructions (EA) -
Electronic module (Interface measurement)
Installation instruction
Levelflex M, FMP40, FMP41C, FMP43, FMP45
Installation Instructions (EA) -
Levelflex M FMP43
Approval No.: KEMA 02 ATEX 1109
II 1/2 D, II 2 D, II 1/3 D, II 3 D
Protection: Ex tD xx IP68 Txx°CEx Safety Instructions (XA) -
Safety Instructions
Levelflex M FMP40, FMP43, FMP45
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex emb [ia] IIC T6...T1
GYJ101291 (NEPSI)Ex Safety Instructions (XA) -
Safety Instructions
Micropilot M, Levelflex M, Prosonic M
FM Control Drawing
EMC C-module for ToF apparatus
Cl. I, II, III, Div. 2, Group A, B, C, D, E, F, G
and Cl. I, Zone 2, Group IIC
NIFW installationEx Safety Instructions (XA) -
Safety Instructions
Levelflex M FMP40, FMP43, FMP45
PROFIBUS PA, FOUNDATION Fieldbus
Ex ia IIC T6...T1
GYJ111018 (NEPSI)Ex Safety Instructions (XA) -
Levelflex M FMP43
Approval No.: KEMA 02 ATEX 1109
II 1/2 G, II 2 G, II 1/2 D, II 1/3 D, II 3 D
Protection: Ex ia IIC T6...T1, Ex tD xx IP68Txx°CEx Safety Instructions (XA) -
Levelflex M FMP40, FMP43, FMP45
Approval No.: EG 05 017-b
II 3 G
Protection: Ex nA II T6...T1 XEx Safety Instructions (XA) -
Levelflex M FMP43
Approval No.: KEMA 02 ATEX 1109
II 1/2 D, II 2 D, II 1/3 D, II 3 D
Protection: Ex tD xx IP68 Txx°CEx Safety Instructions (XA) -
Safety Instructions
Levelflex M FMP40, FMP43, FMP45
4-20 mA HART
Ex ia IIC T6...T1
GYJ111018 (NEPSI)Ex Safety Instructions (XA) -
Levelflex M FMP43
Approval No.: KEMA 02 ATEX 1109
II 2 G
Protection: Ex e mb [ia] IIC T6...T1Ex Safety Instructions (XA) -
Levelflex M FMP43
Approval No.: KEMA 02 ATEX 1109
II 1/2 G, II 2 G
Protection: Ex d [ia] IIC T6...T1Ex Safety Instructions (XA) -
Levelflex M FMP43
Approval No.: KEMA 02 ATEX 1109
II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1Ex Safety Instructions (XA) -
Levelflex M FMP43
Approval No.: KEMA 02 ATEX 1109
II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1Ex Safety Instructions (XA) -
Safety Instructions
Levelflex M FMP40, FMP43, FMP45
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex d ia [ia Ga] IIC T6...T1 Ga/Gb
GYJ12.1261X (NEPSI)Ex Safety Instructions (XA) -
Levelflex M FMP43
Approval No.: KEMA 02 ATEX 1109
II 1/2 D, II 2 D, II 1/3 D, II 3 D
Protection: Ex tD xx IP68 Txx°CEx Safety Instructions (XA) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2179 C, 960409-2180 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1178 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1172 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2170 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2176 C, 960409-2177 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1179 C, 960409-1180 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1171 D, 960409-1174 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1173 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1170 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1176 C, 960409-1177 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2173 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2175 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2178 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2171 D, 960409-2174 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2172 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2172 E
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1175 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP41C, FMP43, FMP45
Functional Safety Manual
Guided level-radar for liquids and bulk solids
Special Documentation (SD) -
Levelflex M FMP40, FMP41C, FMP43, FMP45
Functional Safety data sheet / Datenblatt zur Funktionalen Sicherheit
Special Documentation (SD) -
Levelflex M FMP40, FMP41C, FMP43, FMP45
Micropilot M FMR230, FMR231, FMR240, FMR244, FMR245, FMR250
Hinweis zur Montage
Füllstand-Radar für Flüssigkeiten und Schüttgütern
Geführtes Füllstand-Radar für Flüssigkeiten und SchüttgüterSpecial Documentation (SD) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Manufacturer Information (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Manufacturer Information (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Manufacturer Information (MI) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Please fill in. (You can find example text among the HELP menu)
Please fill in. (You can find example text among the HELP menu)
Manufacturer Information (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Manufacturer Information (MI) -
Please fill in. (You can find example text among the HELP menu)
Please fill in. (You can find example text among the HELP menu)
Manufacturer Information (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Nap&
281;dy i Sterowanie kwiecie&
324; 2007
Detekcja ko&
324;ca sondy
w radarach falowodowychPublications (PU)04/07Lehçe -
Guided Wave Radar provides continuous level measurement of
powdered milk for butter manufacturing
Level measurement needed for 34 foot tall, 150,000 lb tank of powdered
milk done with Levelflex M FMP43 top mounted level transmitter.
Fluctuations in the density, temperature, or build-up do not influence
the measurement.Case Studies (CS)06/10İngilizce -
Levelflex M Guided Level-Radar via PROFIBUS PA o the PlantPAx Process
Automation System
System using a 1788HP-EN2PA Linking Device
Integration DocumentSystem Partner (SP)05/09İngilizce -
Levelflex M Guided Level-Radar via HART to the PlantPAx Process
Automation System
System using a ControlLogix 1756 HART Analog Input Module
Integration DocumentSystem Partner (SP)01/09İngilizce -
GSD Single, GSD_EH_PA_LE_Levelflex_0x152D_V01_00_PALIB, 14.04.2014 (Level
, Levelflex M, 0x152D)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, EH_FF_LE_LevelflexM_0x1012_0x04_0x03_FFLIB_ITK5_20, 09.11.201
6 (Level, Levelflex M, 0x1
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.20Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_LE_LevelflexM_0x152D_0x04_0x01, 07.01.2019 (Level, Levelflex M, 0x152D)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_LevelflexM_0x1012_0x04_0x02_FFLIB_ITK5_00, 09.11.201
6 (Level, Levelflex M, 0x1
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.00Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_LevelflexM_0x1012_0x04_0x01_FFLIB_ITK4_61, 09.11.201
6 (Level, Levelflex M, 0x1
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.61Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_LevelflexFMP4x_0x0012_0x04_0x05, 01.10.2015 (Level, Levelflex M)
HART,
PDM Version: 6.0 SP5, 6.1, 8.1, 8.1 SP1, 8.2Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, LevelflexM_FMP4x_FF_V4_xx_DevRev4, 22.10.2020 (Level, Levelflex M, 0x1012)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, LevelflexM_FMP4x_PA_V4_xx, 20.10.2020 (Level, Levelflex M, 0x152D)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, LevelflexM_FMP4x_V4_xx, 23.10.2020 (Level, Levelflex M, 0x0012)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_FF_Package_Level_1_05_00, 29.05.2018 (Level)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02, R3.12Faceplate1.05.00Language neutral -
Levelflex, Levelflex M
Product Code: FMP43-, FMP53-
Declaration Number: FDA_00170_01.17FDA DeclarationAlmanca , İngilizce -
Product Family: Levelflex M
Product Code: FMP40-, FMP45-, FMP41C-, FMP43-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 04, DD-ITK 5.20Fieldbus Conformanceİngilizce
Aksesuarlar / Yedek parçalar
-
-
Order code 52006628
Instrument plug M20-M12 "PA" (WDM)150
4-pin metall plug for installation in the device, providing connection to a T-Box (WDM) or cable socket (WDM). Cable length: 150mm. Not suitable for PROMAG and PROMAG.
-
-
-
Nr 12 Order code 535720-9020
Set of screws housing F12/T12/F23
Consists of: 1x stop screw M5x10. 1x retaining screw M8x10. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.
-
-
-
Order code 543199-0001
Protective cover for housing T12/F12, SS
Usage: Micropilot M, Micropilot S, Prosonic M, Levelflex M. Material: 316Ti.
-
-
-
Nr 20 Order code 517391-0011
Cover F12/T12 Alu, coated, gasket
Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.
-
Nr 20 Order code 52005936
Cover F12/T12 Alu, window, gasket
Material: aluminium. Usage: VU331, housing F12/T12, Micropilot M/S, Prosonic M, Levelflex M.
-
Nr 20 Order code 52018670
Cover F23 316L, sight glass, gasket
Material: 316L. Usage: VU331, Levelflex M, Micropilot M.
-
Nr 20 Order code 52018671
Cover F23 316L, gasket
Material: 316L. Usage: Levelflex M, Micropilot M.
-
-
-
Nr 25 Order code 518710-0020
Cover T3/T12 Alu, coated, gasket
Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231,FMR240/FMR244/ FMR245, FMR250, FMR530/FMR531/FMR532/ FMR533, FMR540, FMU40/FMU41/FMU42.
-
-
-
Nr 11 Order code 52006026
Cover terminal compartment F12/F23
Hood terminal compartment. Usage: Micropilot M, Prosonic M, Levelflex M.
-
Nr 11 Order code 52019062
Cover terminal compartment F12/F23,FHX40
Hood terminal compartment. Usage: separate display, Micropilot M, Prosonic M, Levelflex M.
-
-
-
Nr 35 Order code 52006197
Terminal module 4-pole, HART, 2-wire
Cable connection. Usage: housing F12/F23, Micropilot M, Levelflex M, Prosonic M.
-
Nr 35 Order code 52012156
Terminal module 4-pole, PA, FF
PROFIBUS PA, FOUNDATION Fieldbus. Usage: Micropilot II/M, Prosonic M, Levelflex M.
-
Nr 35 Order code 52013302
Terminal mod. Ex d, 4-pol., 2wr,HART,T12
Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.
-
Nr 35 Order code 52013303
Terminal mod. Ex d, 2-pol.,2wr,PA/FF,T12
2-wire, PROFIBUS PA/FOUNDATION Fieldbus. Ex d limiter. Usage: housing T12, Levelflex M, Micropilot M, Prosonic M.
-
Nr 35 Order code 52018949
Terminal mod. 4-pol.,EEx ia,HART,T12,OVP
4-pole, 2-wire. OVP = overvoltage protection. Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.
-
Nr 35 Order code 52018950
Terminal mod. 2-p.,EEx ia,PA/FF,T12,OVP
2-pole, 2-wire. PROFIBUS PA, FOUNDATION Fieldbus. OVP = overvoltage protection. Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.
-
-
-
Nr 11 Order code 52005643
Hood housing T12
Cable compartment, electronics side. Usage: Micropilot M/S, Prosonic M, Levelflex M.
-
-
-
Nr 35 Order code 52013304
Power supply 10.5-32VDC (housing F12)
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
Nr 35 Order code 52013305
Power supply 90-250VAC (housing F12)
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
Nr 35 Order code 52015585
Power supply CSA, 10.5-32VDC (housg F12)
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
Nr 35 Order code 52015586
Power supply CSA, 90-250VAC (housg F12)
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
-
-
Nr 40 Order code 52026443
Display VU331, version 2
Alphanumeric display, 4-line. Usage: FMR530/532/533, FMR540, FMU40/41/42/43/44.
-
-
-
Order code 52013874
-
Order code FHX40-
Display FHX40
Remote display + local operation. 4-line LC-display. :: Menu driven plain text operation. :: Easy setup. :: User language selectable. :: Envelope curve display on site. Usage: FMG60, FMU40/FMU41/FMU42/FMU43/FMU44.
-
-
-
Nr 52 Order code 71043425
Aseptic coupling DIN11864-1 A DN25 tube
DIN11864-A, 316L. Slotted nut DIN11851 F25. Electro-polished. Usage: FMP53.
-
Nr 52 Order code 71043426
Dairy fitting DIN11851 DN40 PN40
Material: 316L. Slotted nut DIN11851 F40. Usage: FMP53.
-
Nr 52 Order code 71043427
Dairy fitting DIN11851 DN50 PN40
Material: 316L. Slotted nut DIN11851 F50. Usage: FMP53.
-
Nr 52 Order code 71043428
Adapter NEUMO BioControl DN25 PN16
Flange adapter. Material: 316L. Electro-polished. Usage: FMP53.
-
Nr 52 Order code 71043429
Tri-Clamp ISO2852 DN25-38 1..1-1/2"
Material: 316L. Electro-polished. Usage: FMP53.
-
Nr 52 Order code 71043430
Tri-Clamp ISO2852 DN40-51 2"
Material: 316L. Electro-polished. Usage: FMP53.
-
Nr 52 Order code 71043438
Tri-Clamp ISO2852 DN70-76.1 3"
Material: 316L. Electro-polished. Usage: FMP53.
-
Nr 52 Order code 71043439
-
Nr 52 Order code 71043440
-
Nr 52 Order code 71043443
Aseptic coupl.DIN11864-1 A DN25 tube,3.1
DIN111864-A, 316L. Slotted nut DIN11851 F25. Electro-polished. EN10204-3.1 material (316L wetted parts), inspection certificate. Usage: FMP53.
-
Nr 52 Order code 71043444
Dairy fitting DIN11851 DN40 PN40, 3.1
Material: 316L. Slotted nut DIN11851 F40. EN10204-3.1 material (316L wetted parts), inspection certificate. Usage: FMP53.
-
Nr 52 Order code 71043445
Dairy fitting DIN11851 DN50 PN40, 3.1
Material: 316L. Slotted nut DIN11851 F50. EN10204-3.1 material (316L wetted parts), inspection certificate. Usage: FMP53.
-
Nr 52 Order code 71043446
Adapter NEUMO BioControl DN25 PN16, 3.1
Flange adapter. Material: 316L. Electro-polished. EN10204-3.1 material (316L wetted parts), inspection certificate. Usage: FMP53.
-
Nr 52 Order code 71043447
Tri-Clamp ISO2852 DN25-38 1..1-1/2", 3.1
Material: 316L. Electro-polished. EN10204-3.1 material (316L wetted parts), inspection certificate. Usage: FMP53.
-
Nr 52 Order code 71043448
Tri-Clamp ISO2852 DN40-51 2", 3.1
Material: 316L. Electro-polished. EN10204-3.1 material (316L wetted parts), inspection certificate. Usage: FMP53.
-
Nr 52 Order code 71043449
Tri-Clamp ISO2852 DN70-76.1 3", 3.1
Material: 316L. Electro-polished. EN10204-3.1 material (316L wetted parts), inspection certificate. Usage: FMP53.
-
Nr 52 Order code 71043450
Adapter SMS 2" PN25, 316L, 3.1
Slotted nut. EN10204-3.1 material (316L wetted parts), inspection certificate. Usage: FMP53.
-
Nr 52 Order code 71043451
Adapter SMS 1-1/2" PN25, 316L, 3.1
Slotted nut. EN10204-3.1 material (316L wetted parts), inspection certificate. Usage: FMP53.
-
-
-
Order code 71041381
Weld-in adapter M24 D65, 316L
Flush mount process connection. Core hole: 65mm. Material: 316L. Seal: EPDM O-ring FDA, EHEDG, 3-A compliant. Usage: FMP53, FTL33, FTW23, FTW33, PMP23, PTP33B.
-
Order code 71041383
Weld-in adapter M24 D65, 316L, 3.1
Flush mount process connection. Core hole: 65mm. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: EPDM O-ring. FDA, EHEDG, 3-A compliant. Usage: FMP53, FTL33, FTW23, FTW33, PMP23, PTP33B.
-
-
-
Nr 57 Order code 71043452
Sealing kit FMP43,FMP53 Kalrez, 2 pieces
Consists of: O-ring 9.25x1.78 FFKM 70 Kalrez FDA. Rod/process connection. O-ring 15.54x2.62 FFKM 70 Kalrez FDA. Sensor body/process connection. Usage: FMP43, FMP53.
-
Nr 57 Order code 71043453
Sealing kit FMP43, FMP53 EPDM, 2 pieces
Consists of: O-ring 9.25x1.78 EPDM FDA. Rod/process connection. O-ring 15.54x2.62 EPDM FDA. Sensor body/process connection. Usage: FMP43, FMP53.
-
-
-
Order code 52018204
Adaption kit housing F12, 2-wire, FHX40
Modification to remote display. Housing F12, 2-wire electronics. Non-hazardous area only. Please order FHX40 separately. Usage: Micropilot II/M, Prosonic M, Levelflex M.
-
Order code 52018205
Adaption kit housing F12, 4-wire, FHX40
Modification to remote display. Housing F12, 4-wire electronics. Non-hazardous area only. Please order FHX40 separately. Usage: Levelflex M, Prosonic M.
-
Order code 52016334
Cable FHX40, 20m
Connection cable, doubled shielded. Usage: FHX40.
-
Order code 71020502
Cable FHX40, 5m
Connection cable, doubled shielded. Usage: FHX40.
-
Order code 71020503
Cable FHX40, 10m
Connection cable, doubled shielded. Usage: FHX40.
-
Order code 71020504
Cable FHX40, 30m
Connection cable, doubled shielded. Usage: FHX40.
-
Order code 71041379
Protective cover FMP43/53
Material: 316L. O-ring EPDM 62.7x1.78mm. Grounding screw. Usage: FMP43, FMP53, housing detachable.
-
Order code 71041382
Calibration kit FMP53
Consists of: Adapter, HF-cables, Terminator, Instruction. Usage: FMP53.
-
Order code
Phase out spares
-
Order code
12/2017
-
-
Yeni seri
-
Özelleştirilmiş ürünler
- Zorlu uygulamalar için tasarlanmış
Teknik mükemmellik
Sadelik
Değişken
FLEX seçimleri Teknik mükemmellik Sadelik - F
- L
- E
- X
Fundamental seçim
Temel ölçüm ihtiyaçlarınızı karşılayın
Teknik mükemmellik Sadelik - F
- L
- E
- X
Lean seçim
Ana proseslerinizin üstesinden kolayca gelin
Teknik mükemmellik Sadelik - F
- L
- E
- X
Extended seçim
Proseslerinizi yenilikçi teknolojilerle optimize edin
Teknik mükemmellik Sadelik - F
- L
- E
- X
Xpert seçim
En zorlu uygulamalarınızda uzmanlaşın
Teknik mükemmellik Sadelik Değişken
-