Ultrasonic measurement
Time-of-Flight
Prosonic FMU43

Prosonic FMU43 ©Endress+Hauser

Time-of-Flight measuring principle

Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 15m

The Prosonic FMU43 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.

  • Avantajlar

    • Reliable non-contact measurement

    • Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable

    • Envelope curves on the on-site display for simple diagnosis

    • Hermetically sealed and potted sensor

    • ...

  • Uygulama alanı

    Two-wire or four wire instrument for continuous non-contact level and flow measurement.

    • Process connection: Flange

    • Temperature: -40 to +80°C (-40 to +176°F)

    • Pressure: +0.7 to +2.5bar (+10 to +36psi)

    • Maximum measuring distance: Liquids 15m (50ft),...

Details

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus

  • Accuracy

    +/- 4 mm or +/- 0.2 %of set measuring range 1)

  • Ambient temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process pressure absolute / max. overpressure limit

    0.7 bar ... 2.5 bar abs
    (10 psi ... 36 psi)

  • Main wetted parts

    unsaturated polyester, 316 Ti

  • Process connection

    DN 100, ASME 4"

  • Blocking distance

    0.6 m (2 ft)

  • Max. measurement distance

    7 m (23 ft)

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, NEPSI

  • Application limits

    Take notice of range diagram

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus

  • Accuracy

    +/- 4 mm or +/- 0.2 %of set measuring range

  • Ambient temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process pressure absolute / max. overpressure limit

    0.7 bar ... 2.5 bar abs
    (10 psi ... 36 psi)

  • Main wetted parts

    Unsaturated Polyester, 316 Ti

  • Process connection

    DN 100, ASME 4"

  • Blocking distance

    0.6 m (2 ft)

  • Application

  • Max. measurement distance

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, NEPSI

  • Application limits

Dokümanlar / Kılavuzlar / Yazılım

Aksesuarlar / Yedek parçalar

Nr
Order code
Specification
  • Önceki seri