Micropilot M FMR230

This product is no longer available.

Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.

Özellikler ve şartlar

Geri

Details

  • Measuring principle

    Level radar

  • Characteristic / Application

    For high pressures and temperatures

  • Supply / Communication

    2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)

  • Frequency

    C-band (~6 GHz)

  • Accuracy

    +/- 10 mm

  • Ambient temperature

    -40 °C...+80 °C

    (-40 °F...+176 °F)

  • Process temperature

    -60 °C...+400 °C

    (-76 °F...+752 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum...160 bar

    (Vacuum...2320 psi)

  • Main wetted parts

    316L, Alloy C

  • Process connection

    Flange:

    DN80...DN250,

    ASME 3"...10",

    JIS 10K

  • Process connection hygienic

    Tri-Clamp ISO2852

  • Application

  • Max. measurement distance

    20 m (65 ft)

  • https://portal.endress.com/picpool/sft/prodcont/technicalinfo/Radar_Mediengruppe_en.jpg https://portal.endress.com/picpool/sft/prodcont/technicalinfo/Radar_not_selected_FMR230.jpg
  • Communication

    4...20 mA HART

    PROFIBUS PA

    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, IECEx, TIIS, NEPSI

    Overfill prevention WHG

    SIL

    EN10204-3.1

    NACE

    Marine GL/ABS/NK

  • Options

    DN80/DN100 for Bypass/Stilling well

  • Application limits

    Maximum measuring range is dependent on the tank form and/or application


    Free space with nozzle

Dokümanlar / Kılavuzlar / Yazılım

Aksesuarlar / Yedek parçalar

Nr
Order code
Specification
  • Önceki seri

  • Yeni seri