Microwave barrier emitter
Soliwave FQR50

Soliwave FQR50 aluminum housing ©Endress+Hauser
Soliwave FQR50 stainless steel housing ©Endress+Hauser

Emitter for non-contact point level detection in bulk solids

The Soliwave FQR50 microwave barrier uses a contact-free procedure for detection of point levels. It can be installed in containers, conduits, shafts or on free fall shafts. It is possible to take a measurement through non-metallic container materials from the outside. Suitable as point level switch for controlling and counting all types of bulk solids. It interacts with the Soliwave FDR50 receiver.

Hızlı seçim

Önerdiğimiz seçeneklerden birini seçin
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

veya

Ayrı konfigürasyon

Seçiminize mümkün olan tüm seçeneklerle devam edin
  • Avantajlar

    • Very reliable measurement thanks to adjustable sensitivity and indication of the signal strength on the receiver

    • Mechanical robust solution ensures cost savings over the whole life cycle of the product: No wear and tear, long serviceable life,...

  • Uygulama alanı

    Typical bulk solids are: Wood chips, wood dust or flour, plaster, cement, ash, paper or cardboard shred, gravel, sand, dried powders in general, bags, boxes.

    • Process connections: Threads

    • Ambient temperature: -20 to +70°C (-4 to +158°F)

    • Measuring range:...

Özellikler ve şartlar

Geri

Details

  • Measuring principle

    Microwave barrier

  • Characteristic / Application

    Contactless measurement
    Microwave transmitter

  • Supply / Communication

    Transmitter

  • Ambient temperature

    -20 °C ... 70 °C
    (-4°F ... 158°F)

  • Process temperature

    Waves emitted from outside (non-contact): any

    Waves emitted within installation (contact):

    -20 °C ... 70 °C
    (-4°F ... 158 °F)

  • Process pressure absolute / max. overpressure limit

    Waves emitted from outside (contactless): any
    Waves emitted within installation (contact):

    0.8 bar abs ... 4.8 bar abs (12 psi ... 70 psi)

  • Min. density of medium

    Solid weight: > 10 g/l

  • Main wetted parts

    Within installation: Aluminium, PTFE
    Or: non-contact

  • Process connection

    1-1/2" G + NPT
    or with waves emitted from outside / mounting from outside, walls of container must not be made of metal

  • Process connection hygienic

    With waves emitted from outside

  • Communication

    Transmitter: Relays, DPDT

  • Certificates / Approvals

    ATEX, IEC Ex

  • Options

    Flange

  • Components

    Reciever: FDR50
    Transmitter: FTR325

  • Successor

    Soliwave FQR57

  • Application limits

    When waves are emitted from outside (non-contact)
    Solid weight: <10g/l

Dokümanlar / Kılavuzlar / Yazılım

Aksesuarlar / Yedek parçalar

Nr
Order code
Specification
  • Yeni seri