Omnigrad S TAF16
High temperature TC thermometer

Omnigrad S TAF16
High temperature TC thermometer ©Endress+Hauser
Omnigrad S TAF16
High temperature TC thermometer ©Endress+Hauser

Applicable for cement production, steel treatment, incinerators and fluidized bed furnaces

Measuring points with extremely high process temperatures require these special thermometers with ceramic or metal thermowells as well as thermocouples made from special metals, such as platinum and rhodium. The thermowell made from special materials protects from mechanical and chemical damages in the process and increases the life span of the used sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.

  • Avantajlar

    • Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance

    • Long term stable measurement due to sensor protection with non-porous materials

    • Flexible product selection by modular design

    • Optimized life cycle costs by...

  • Uygulama alanı

    • Applicable for cement production, steel treatment, incinerators and fluidized bed furnaces. The TAF16 contains a single or double TC insert and a metal or ceramic protection tube.

    • Process temperatures: up to +1700 °C (+3092 °F)

Özellikler ve şartlar

Geri

Details

  • Measuring principle

    Thermocouple

  • Characteristic / Application

    metric style

    modular temperature assembly

    high temperature probe (furnace)

    incl. thermowell / protection tube (metal)

  • Terminal head

    TA20A - aluminium - cover with screws

    TA20D - aluminium - hinged cover high

    TA30A - E+H, aluminium - cover low - w/o. display

    TA30D - E+H, aluminium - cover high

    DIN A - aluminum

  • Thermowell / protection tube

    welded protection tube

    ceramic protection tube

  • Insert / probe

    mineral insulated (MI), flexible

    ceramic capilarry, rigid

  • Outer diameter protection tube / Insert

    14,0 mm (0,55")

    15,0 mm (0,59")

    17,2 mm (0,68")

    18,0 mm (0,71")

    21,3 mm (0,84")

    22,0 mm (0,87")

    26,7 mm (1,05")

    28,0 mm (1,10")

  • Max. immersion length on request

    up to 4.525,00 mm (178,15'')

  • Material protection tube/ thermowell

    1.4401 (316)

    1.4749 (~446)

    1.4841 (310)

    Alloy 600 (2.4816)

    Alloy 601 (2.4851)

    Incoloy 800HT (1.4959)

    Kanthal AF

    Kanthal Super

    NiCo

    Siliciumnitrid(SiN)

  • Process connection

    compression fitting:

    G1/2"

    G3/4"

    G1"

    G11/4"

    G11/2"

    adjustable Flange

  • Tip shape

    straight

  • Operating temperature range

    Type K:

    -40 C ...1.100 C

    (-40 F ...2.012 F)

    Type J:

    -40 C ...750 C

    (-40 F ...1.382 F)

    Type N:

    -40 C ...1.150 C

    (-40 F ...2102 F)

    Type S:

    0 C ...1.400 C

    (32 F ...2.552 F)

  • Max. process pressure (static)

    at 20 °C: 1 bar (15 psi)

  • Accuracy

    class 2 acc. to IEC 60584

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Certification

    SIL (transmitter only)

Dokümanlar / Kılavuzlar / Yazılım

Aksesuarlar / Yedek parçalar

Nr
Order code
Specification
  • B
    • Nr B Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr B Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr B Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

  • B
    • Nr B Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr B Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.