This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.

Önceki seri
-
Yeni seri
-
Özelleştirilmiş ürünler
- Zorlu uygulamalar için tasarlanmış
Teknik mükemmellik
Sadelik
Değişken
FLEX seçimleri Teknik mükemmellik Sadelik - F
- L
- E
- X
Fundamental seçim
Temel ölçüm ihtiyaçlarınızı karşılayın
Teknik mükemmellik Sadelik - F
- L
- E
- X
Lean seçim
Ana proseslerinizin üstesinden kolayca gelin
Teknik mükemmellik Sadelik - F
- L
- E
- X
Extended seçim
Proseslerinizi yenilikçi teknolojilerle optimize edin
Teknik mükemmellik Sadelik - F
- L
- E
- X
Xpert seçim
En zorlu uygulamalarınızda uzmanlaşın
Teknik mükemmellik Sadelik Değişken
-
-
Measuring principle
Guided radar
-
Characteristic / Application
Characteristic / Application
-
Interface measurement
Clean interfaces liquid / liquid
Simultaneous measurment of interface and overall level -
Supply / Communication
2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)
-
Accuracy
Accuracy
-
Ambient temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F) -
Process temperature
-40 °C ... 150 °C
(-40 °F ... 302 °F) -
Process pressure absolute / max. overpressure limit
Vacuum ... 40 bar
(Vacuum ... 580 psi) -
Main wetted parts
Main wetted parts
-
Process connection
G + NPT 3/4" and 1 1/2", DN40 ... DN150
-
Sensor length
Rod: 4m (178")
Coax: 4m (178")
Rope: 35m (1378") -
Application
Application
-
Max. measurement distance
Max. measurement distance
-
Communication
4 ... 20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Certificates / Approvals
ATEX
FM
CSA
TIIS
WHG/ Overfill prevention
SIL
NACE
GL Marine
EN10204-3.1
IECEx -
Successor
FMP50,FMP51
-
Application limits
Application limits
-
Measuring principle
Guided radar
-
Characteristic / Application
Powdered or granular solids
Suitable for measurement with heavy dust production -
Supply / Communication
2-wire 16-36V, DC
4-wire 10,5-32V, DC
4-wire 90-250V, 50/60Hz -
Ambient temperature
-40 °C ... +80 °C
(-40°F ... 176 °F) -
Process temperature
-40 °C ... +150 °C
(-40°F ... 302°F) -
Process pressure absolute / max. overpressure limit
Vacuum...40bar
(Vaccum...580psi) -
Main wetted parts
316, PTFE
-
Process connection
3/4" + 1-1/2" G+NPT
Flange >=DN40 -
Blocking distance
Top: 200mm (7.87")
Bottom: 250mm (9.87") (Rope probe) -
Sensor length
Rod probe: 4m (13ft)
Rope probe: 35m (115ft) -
Max. measurement distance
35m (115ft)
-
Communication
4 ... 20mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Certificates / Approvals
ATEX
FM
CSA
TIIS
WGH
SIL
NACE
EN10204-3.1 -
Options
Separate electronics, separate display
-
Successor
FMP56, FMP57
-
Successor
FMP56, FMP57
-
Application limits
Dk <= 1,6