Guided radar measurement
Time-of-Flight
Levelflex FMP53

For the highest hygiene requirements in the food and life sciences industry

  • Levelflex FMP53 ©Endress+Hauser
  • Time-of-Flight measuring principle

  • Commissioning movie for Levelflex FMP5x guided radar and Micropilot FMR5x free space radar

  • Unique HistoROM data management concept for safe level measurement

  • Continuous adapting algorithms offering safe level measurement due to Multi-Echo Tracking

  • Multi-Echo Tracking with Tank Trace marks and traces all echoes signals, not only the level signal - guaranteeing safe measurement at any time

  • Levelflex FMP53 ©Endress+Hauser

Levelflex FMP53 for continuous level measurement for hygienically sensitive applications in the food and life sciences industry. FMP53 meets the hygiene requirements according to ASME BPE and USP Class VI. The unique in situ validation without dismantling from the process is a cost saving advantage. FMP53 guided radar offers maximum reliability even in case of moved surface and foam, for changing medias and in case of filling via spray head.

Avantajlar

  • Reliable measurement even for changing product and process conditions

  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

  • Highest reliability due to new Multi-Echo Tracking evaluation

  • Hardware and software developed according to IEC 61508 up to SIL3

  • Seamless integration into control or asset management systems

  • Intuitive, menu-guided operation concept (on-site or via the control system) in national languages reduces costs for training, maintenance and operation

  • World's easiest proof test for SIL and WHG saves time and costs

Uygulama alanı

Version with rod probe.

  • Process connections: For hygiene requirements (Tri-Clamp, 11851, 11864, NEUMO,
    Varivent N, SMS)

  • Temperature: -20 to +150°C (-4 to +302°F)

  • Pressure: -1 to +16bar (-14.5 to +232psi)

  • Maximum measuring range: Rod 6m (20ft)

  • Accuracy: ±2mm (0.12")

  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, 5-point linearity protocol

Özellikler ve şartlar

Dokümanlar / Kılavuzlar / Yazılım

Aksesuarlar / Yedek parçalar

Önceki seri / Yeni seri

Önceki: Levelflex M FMP43, Float Gauge LTC2230

İletişim

Endress Hauser A.Ş.
Büyükdere Cad. No:103 Şarlı İş Merk. 8.Kat 34394 Mecidiyeköy/İstanbul , Türkiye
Tel.: 0212 275 1355
Faks: 0212 266 2775
E-posta gönder www.tr.endress.com

İlgili haberler

Online Araçlar